Audit · VENDORS

Selling software to Polish hospitals: what NIS2 contracts will require from vendors

Remote Admin Audit Team·November 23, 2026·22 min read

Polish hospitals that qualify as essential or important entities under Poland’s NIS2 law stay responsible for the security of their systems even when an outside company maintains them. The law requires them to secure their ICT supply chain, and the contract with the supplier is the strongest proof that they have done so. If you are a medical software vendor, expect hospital customers to ask for an incident notification deadline counted in hours, controlled remote access, vulnerability handling with deadlines, a right to audit and a tested exit plan.

A medical software vendor usually has wider access to patient data than most of the hospital’s own staff. Your engineers administer the database behind the hospital information system, connect remotely to servers, install updates and are often the only people who understand how the data is structured. If one of your service accounts is taken over, or your support desk stops answering, the hospital and its patients bear the consequences. This article explains what the law demands from your customers, which clauses to expect and what evidence to have ready. Legal status as of November 2026. This article is for information only and is not legal advice. We review vendor contracts and vendor access for healthcare providers as part of our NIS2 / KSC audit.

The supply-chain duty: what the KSC Act requires from your customers

Poland transposed the NIS2 directive through its National Cybersecurity System Act (the KSC Act), amended by the Act of 23 January 2026 (Journal of Laws 2026, item 252, in Polish) and in force in its new form since 3 April 2026. An essential or important entity has to run an information security management system (ISMS). One required element is the security and continuity of the supply chain of ICT products, services and processes on which the provision of the service depends, taking into account the relationship with the direct supplier of hardware or software (Article 8(1)(2)(e) of the KSC Act).

When it implements these measures, the entity takes into account (Article 8(2)):

  • vulnerabilities related to the supplier of hardware or software,
  • the overall quality of the ICT products, services and processes that come from the supplier,
  • the results of the coordinated security assessment carried out at EU level by the Cooperation Group,
  • the results of proceedings to designate a supplier as a high-risk supplier (Article 67b).

Three more elements of the same article involve suppliers: security in the acquisition, development, maintenance and operation of the system, including its testing (Article 8(1)(2)(b)); regular software updates in line with the manufacturer’s recommendations, with an analysis of their impact on the service (Article 8(1)(5)(b)); and immediate action once a vulnerability has been noticed (Article 8(1)(5)(d)). A hospital cannot do any of these without the producer, who holds the code and the knowledge of the system.

The responsibility cannot be moved to you by contract. The head of the entity, meaning the management board of a private provider or the director of a public hospital, is responsible for these obligations even after entrusting them to another person (Article 8c). Entities that met the criteria on 3 April 2026 have until 3 April 2027 to implement them, so contracts signed today should already carry the final wording.

The Act does not cover every healthcare provider. Status depends on the type and size of the entity, which a provider can check in our free Regulatory Compass survey. The full list of duties is in our article on Poland’s KSC Act for healthcare providers.

Does the KSC Act dictate the content of a vendor contract?

No, the KSC Act contains no list of mandatory contract clauses. It requires a result, a secure and continuous supply chain, and leaves the choice of measures to the entity, which matches them to the risk it has assessed. The contract is, however, the only tool a hospital has for binding an outside company to specific behaviour, so each hospital writes its own requirements. The Council of Ministers may also specify ISMS requirements for particular types of activity in a regulation (Article 8a), so check the current state of the implementing rules before a large tender.

Some contract terms do follow directly from provisions that apply to every healthcare provider in Poland, including providers outside the KSC Act.

Provision What it means for the contract with a vendor
Article 28 of the GDPR A vendor with access to patient data processes it on behalf of the provider, so a data processing agreement is needed.
Article 24(2)(2) and 24(3) of the Patient Rights Act (in Polish) People who maintain the IT system and look after its security process data from medical records on the basis of an authorisation issued by the data controller, and they are bound by secrecy.
Article 24(5)–(7) of the same Act Performance of the processing agreement must not disrupt the provision of healthcare services, in particular access to records without undue delay. A processor that stops processing the data, for example because it is being wound up, hands the data over to the provider.
§ 1(6)(8) of the medical records regulation (in Polish) The system must allow all data to be exported in the applicable standards and formats so that it can be restored in another system.

How will a hospital classify you as a supplier?

A hospital classifies each supplier by what it can access and what happens when it fails, and the resulting tier decides how many requirements you will see. The Act speaks of suppliers on which the provision of the service depends, and in a hospital that is more companies than the producer of the main system. The starting point is a list of every company that has an account, a tunnel, a server or code in the hospital’s infrastructure.

Supplier Typical access Effect of failure or hijacked access Tier
Producer and maintainer of the hospital information system (HIS) and the electronic medical records (EDM) repository Administrative accounts in the application and the database, remote service, updates No records on the wards, risk of the patient database being leaked or encrypted Critical
Suppliers of imaging systems (RIS/PACS) and laboratory systems (LIS) Application servers, integrations with the HIS, remote service Diagnostics halted, results and images lost Critical
Hosting company, data centre, supplier of a system delivered as a service Control over servers and backups All hosted systems unavailable at the same time Critical
Company administering the network, servers or workstations Administrator rights to the domain, firewalls and backups One hijacked account gives control over the whole environment Critical
Service company for networked medical equipment Remote connections to devices and reporting workstations A way into the clinical network that bypasses perimeter defences Significant
Supplier of a patient portal, online booking or teleconsultation platform Patient data reachable from the internet, integration with the HIS Data leak, takeover of patient accounts, booking unavailable Significant

Suppliers of HR and finance systems and the connectivity operator usually land in a standard tier. The classification tends to follow four steps:

  1. The hospital lists its suppliers from the contract register, the accounts in the domain and in the medical systems, and the VPN and firewall configuration. The technical sources reveal companies that procurement no longer remembers.
  2. It assigns a tier to each. A critical supplier is one without which the hospital cannot admit a patient, or one that has administrative access to medical data.
  3. For critical suppliers it appoints a contract owner and records the acceptable downtime of the system, agreed with the wards.
  4. It compares current contracts with a list of clauses like the one below and enters the gaps in the risk assessment and the risk treatment plan, which belong to the documentation the Act requires (Article 10).

Ask the customer which tier it has put you in and what downtime the wards have accepted, because that figure drives the service levels you will be asked to sign. Step one usually turns up old accounts and tunnels that a vendor’s team created years ago. Close yours before the hospital’s review finds them. We described the general criteria applied to hosting and service companies in our guide on how to evaluate a hosting or IT provider for NIS2 and DORA.

What contract clauses should a medical software vendor expect?

A medical software vendor classified as critical should expect clauses in nine areas: service levels, incident notification, vulnerabilities and updates, remote access, audit rights, subcontractors, data export and exit, data processing, and backups and continuity. Suppliers in the significant tier usually receive the rows that match their access. A clause that nobody verifies stops working after a year, so a careful hospital attaches a check to each one. Plan for those checks as recurring work.

Area What the hospital will ask for How it will check
Service levels (SLA) Separate response time and restoration time for critical, serious and ordinary faults. Round-the-clock support for systems used round the clock. Financial consequences when the times are exceeded. A monthly ticket report compared with the hospital’s own fault log.
Incident notification Notification within a deadline stated in hours of any incident affecting the hospital’s systems or data, and of incidents at the vendor that may affect the hospital. A 24/7 channel, preservation of logs, cooperation on the hospital’s own notifications. A test notification once a year, an up-to-date contact list.
Vulnerabilities and updates Information about vulnerabilities in the product and its components, patch deadlines that depend on severity, a list of supported versions, end-of-support notice given months in advance. A quarterly patch summary, a vulnerability scan after each update.
Remote access Only through a channel controlled by the hospital, with multi-factor authentication, on named accounts, for the duration of a ticket, with sessions recorded. A quarterly review of accounts and the session log.
Right to audit The right to inspect the vendor or to receive the results of independent audits and tests. A deadline for fixing findings. The vendor’s participation in audits and inspections at the hospital. A yearly review, a register of findings with closing dates.
Subcontractors A list of subcontractors with access to systems or data, advance notice of changes, the same requirements passed down, full liability of the vendor. The list updated at the annual review.
Data export and exit plan Export of all data on request, also during the contract, in the formats required by law. A transition period, migration support, deletion of data confirmed by a signed record. A trial export and restore of a sample in a test environment.
Data processing Scope of data, security measures, sub-processing, a deadline for reporting breaches, return or deletion of data. A list of people with access, by name, and their authorisations. A yearly review with the data protection officer.
Backups and continuity Who makes the backups, where they are stored, how often restores are tested. In the as-a-service model, also the vendor’s own business continuity plan. A restore test record available to the hospital.

For critical suppliers hospitals add two more items: the hospital’s access to the logs of administrator activity, and change management, which covers advance notice of updates, maintenance windows and a rollback plan.

The incident notification deadline

A hospital reports a serious incident to CSIRT CeZ, the sectoral CSIRT for health run by Centrum e-Zdrowia (the e-Health Centre, CeZ), in stages: an early warning within 24 hours of detection, an incident notification within 72 hours and a final report within one month of the notification (Article 11(1)(4)–(4c)). If the event starts on your side and you tell the hospital a week later, the hospital cannot meet its own duties properly. The contract should therefore state a deadline in hours and not rely on “without undue delay”. A reasonable arrangement is a few hours from the moment the event is established for the first message, so that the hospital has enough time to assess the situation and send its early warning.

To meet such a clause you need a contact channel that works at night, a person on call who is allowed to inform customers, and a short template for the first message. A separate duty is the notification of a personal data breach to the Polish data protection authority (UODO) within 72 hours (Article 33 of the GDPR), so as a processor you should report personal data breaches as well. We describe the hospital’s side of the procedure in our article on reporting a cyber incident to CSIRT CeZ.

Remote service access

A permanent tunnel and a single “service” account shared by the vendor’s whole team is one of the most dangerous practices in a supplier relationship, and you should expect the contract to rule it out. Technicians connect through a channel the hospital controls, log in with multi-factor authentication to named accounts, and access is switched on for the duration of a specific ticket. Among the required measures the KSC Act lists access-control policies and multi-factor authentication where appropriate (Article 8(1)(2)(l) and (n)), and the administrative account of an outside company is such a case.

For a vendor with many customers this changes how support works. Each engineer needs a personal account at each hospital, your tickets have to carry a reference the hospital can match to a session, and your leaver process has to reach every customer environment. The role and review model on the hospital side is covered in our article on who can access patient data.

Vulnerabilities and updates

According to CSIRT CeZ data presented on 1 October 2026, vulnerable services were the second most frequent category of incidents handled in the Polish health sector in 2025 (344 cases), and credential leaks were the third (148). The contract should settle who delivers a patch and how fast, who installs it, and what happens when the application requires an operating system or a database that is out of support.

Hospitals will also reserve the right to test. The hospital should be able to commission penetration testing of the system and run vulnerability scanning on a regular basis, and the vendor is expected to respond to the results within a set time. Networked medical equipment works differently, because patches are applied according to the device manufacturer’s guidance. We cover that in the article on medical device cybersecurity in hospital networks.

Data export and exit plan

As a rule, medical records in Poland are kept for 20 years from the end of the calendar year in which the last entry was made (Article 29 of the Patient Rights Act). That is longer than a software contract usually lasts, so a change of vendor during that period is very likely. Since the regulations already require the ability to export all data, the contract should make the requirement specific: the time allowed for the export, the formats, documentation of the data structures, pricing agreed in advance and support during the transition period.

One trial export, with a sample restored in a test environment, tells a hospital more about its dependence on a vendor than a page of declarations. Run that exercise internally before a customer asks for it.

Data processing, subcontractors and the right to audit

Because performance of the processing agreement must not disrupt the provision of healthcare services, the contract should not contain a mechanism that lets the vendor cut the hospital off from its records, for example during a payment dispute. The scope of such a term should be assessed with a lawyer. Your employees act under an authorisation issued by the data controller, so the hospital will want to know them by name.

The KSC Act speaks of the relationship with the direct supplier, but the risk does not end at the first link. A software producer often relies on somebody else’s data centre, on external developers or on an implementation partner. The hospital will ask for a list of such companies and require you to pass the same obligations down to them. The right to audit does not have to mean a yearly visit to your office. A review of independent audit and test results is usually enough, and on-site inspection is kept for the period after an incident.

How do hospitals assess a vendor before signing?

Hospitals assess a vendor before signing with a security questionnaire in which every “yes” needs evidence: a document, a description of the configuration or a report. A dozen or so questions with evidence tell a hospital more than a hundred questions answered by the sales team.

CSIRT CeZ recommendations for suppliers of IT solutions

According to the Centrum e-Zdrowia announcement of 1 October 2026 (in Polish), CSIRT CeZ responded to the growing number of attacks on medical entities and on producers of medical software by preparing security recommendations for suppliers of IT solutions for healthcare. They cover, among other areas, security management, data protection, system architecture, access management, and monitoring and incident response. The material was distributed through organisations that bring together software suppliers and producers.

Expect a hospital to ask you in writing whether you know these recommendations and how you address each of the areas listed. We do not quote the content of the recommendations here. If you do not have the current version, ask the industry organisation you belong to, and if in doubt ask CSIRT CeZ.

Sample questionnaire questions

The questions below are our own proposal, arranged by the same areas. They are not a quotation from the recommendations.

  • Security management. Who is responsible for the security of the product, and how can that person be reached outside working hours? Is the company an essential or important entity within the meaning of the KSC Act?
  • Data protection. Where are patient data and their backups physically located? Is real data used for testing and training?
  • System architecture. Which versions of operating systems and databases are supported, and until when? Which components come from third parties, and how are their vulnerabilities tracked?
  • Access management. How many of the vendor’s employees have access to the customer’s environment, and on which accounts? How quickly is access removed when someone leaves the company?
  • Monitoring and incident response. How quickly does the vendor inform customers about an incident? When did it last test its response and recovery procedure?

A sensible hospital scores the evidence, not the number of “yes” answers. The warning signs are usually the same: nobody responsible for security, a refusal to say where the data is located, one service account for all customers, no list of supported versions. Each such point is recorded as a risk to be closed by a clause, by a safeguard on the hospital’s side or by an acceptance signed by the head of the entity. The most useful preparation on your side is an evidence pack that answers these questions once and is then kept current: the security contact and incident channel, the list of supported versions, the list of staff and subcontractors with access, the latest test results you can share and the record of a trial export.

When is a medical software vendor itself covered by the KSC Act?

A vendor is covered by the KSC Act when it falls into one of the entity types listed in Annex 1 or Annex 2 and reaches the size threshold. Supplying software to a hospital does not by itself create that status. In practice four entries come into play.

Type of vendor Possible entry in the Act Size threshold and status
A company that installs, maintains and remotely administers the system at the customer’s site Managed service provider (Annex 1, sector “ICT service management”) Above the thresholds of a medium-sized enterprise: essential entity. Medium-sized enterprise: important entity.
A company that provides the system from its own infrastructure or runs a data centre Cloud computing service provider or data centre service provider (Annex 1, sector “Digital infrastructure”) As above.
A producer of software that is a medical device Manufacturer of medical devices (Annex 2, sector “Manufacturing”) At least a medium-sized enterprise: important entity.
A company that handles incidents or carries out security tests or audits Managed security service provider At least a small enterprise: essential entity (Article 5(1)(3)).

A medium-sized enterprise has fewer than 250 employees and an annual turnover of up to EUR 50 million or a balance sheet total of up to EUR 43 million, and at the same time is no longer small, which means it has at least 50 employees or exceeds EUR 10 million in both turnover and balance sheet total. Smaller producers are, as a rule, outside the Act. The classification of a particular company needs to be checked individually. For a vendor established outside Poland there is the additional question of which country’s rules apply, which this article does not cover and which also needs individual confirmation. Whatever your status, hospitals will ask for a written statement on whether you are entered in the register of essential and important entities.

Your status does not change the hospital’s obligations. A vendor covered by the Act has its own ISMS and its own notification deadlines, which makes the conversation about requirements easier but does not replace the clauses. A vendor outside the Act answers to the hospital primarily within the scope set by the contract. The Act also allows entities and their suppliers to exchange information about vulnerabilities and threats and to conclude arrangements for that purpose (Article 8h).

The high-risk supplier is a separate matter. The minister responsible for digital affairs may designate a supplier of hardware or software used by essential and important entities as a high-risk supplier (Article 67b). After such a decision, entities do not put into use the products and services it covers, and they withdraw those already in use no later than 7 years after the decision is announced (Article 67c(1)).

Who supervises vendors on the hospital side?

The head of the entity is responsible for supervising suppliers, and the day-to-day work is split between the IT department, the person responsible for security, the data protection officer and procurement. Knowing the split helps you send the right document to the right person. Where a hospital has not written it into its ISMS, each of these people tends to assume that someone else is dealing with the vendor.

Role Tasks in relation to vendors
Head of the entity Approves supplier requirements as part of the ISMS, plans the funding, accepts in writing the risks that could not be closed (Articles 8c and 8d).
Person responsible for security (internal or a vCISO) Keeps the supplier register, runs questionnaires and risk assessments, prepares clauses, organises the annual review and the test notifications.
IT department Creates and removes service accounts, guards the remote access channel, verifies SLA reports and the installation of patches.
Data protection officer Gives an opinion on processing agreements, oversees the authorisations of the vendor’s employees, takes part in assessing breaches.
Procurement and legal Maintain the contract template with security clauses, write the requirements into the tender specification, handle annexes.
Heads of clinical units Define how long a ward can work without the system and maintain the downtime procedures.

The record of the annual review of each critical supplier goes into the operational documentation of the ISMS, so the hospital will need your input for it every year.

What happens to contracts signed before the amendment?

Contracts concluded before the amendment do not have to be terminated, but hospitals are bringing them into line in stages, starting with what depends on the hospital alone. If you already have Polish hospital customers, the plan they are likely to follow looks like this:

  1. This week: the hospital switches off permanent tunnels and service accounts that cannot be assigned to a specific person, and turns on multi-factor authentication for the rest. If your support depends on a shared account, it will stop working.
  2. This month: it finishes the supplier map, identifies the critical suppliers, collects their contracts together with the processing agreements and checks the lists of people with access.
  3. This quarter: it sends critical suppliers a questionnaire and a proposed annex covering at least incident notification, remote access, vulnerabilities and data export. It also carries out one trial export.
  4. By 3 April 2027: it closes the annexes, describes the supervision process in the ISMS documentation and carries out the first annual review. Where an annex could not be signed, it records the risk, the compensating safeguards and the decision of the head of the entity.
  5. With every new purchase: it writes the security requirements into the tender specification and the contract template before a contractor is chosen.

Providers that apply the Polish Public Procurement Law must additionally check with a lawyer how far a concluded contract may be changed. Where an annex is not possible, part of the requirements can be introduced technically, by controlling the remote access channel and monitoring the service team’s activity.

Common contract mistakes and how a vendor can avoid them

  • The SLA measures only response time. The vendor confirms the ticket within an hour and the system stays down for three days. Offer a restoration time you can keep for each fault category.
  • Data export “on terms to be agreed”. The terms then get agreed at the moment when the hospital has no negotiating power left. Agree the export scope, formats and pricing when the contract is signed.
  • Requirements only for the main producer. The integrator, the network company and the equipment service team often have equally wide access, and their contracts are sometimes one page long. If you are one of them, the same clauses apply to you as to the HIS producer.
  • No verification. Good clauses exist, but nobody requests the reports, reviews the accounts or rehearses the notifications. Send the monthly report and propose the yearly test notification yourself.

For the technical background, including the risks tied to components and updates, see our article on software supply chain security.

FAQ: frequently asked questions

Does NIS2 apply to a medical software vendor in Poland?

Indirectly always, directly only in some cases. A hospital that is an essential or important entity must ensure the security of its supply chain, so it passes requirements on to the vendor through the contract. The vendor itself is covered by the KSC Act when it falls within Annex 1 or Annex 2, for example as a managed service provider or a medical device manufacturer, and reaches the size threshold.

What should a software contract with a Polish hospital contain?

At a minimum: service levels with a restoration time, an incident notification deadline in hours, rules for handling vulnerabilities and updates, remote access rules, a right to audit, a list of subcontractors, data export with an exit plan, and a data processing agreement.

How quickly must a vendor report an incident to a hospital?

The KSC Act does not set this deadline, so the contract does. It should be expressed in hours and be short enough for the hospital to assess the event and send an early warning to CSIRT CeZ within 24 hours of detecting a serious incident.

Who is responsible for an incident caused by a vendor?

The duties under the KSC Act, including incident notification, are carried out by the healthcare provider, and the head of the entity is responsible for them even when the tasks were entrusted to someone else (Article 8c). The provider also remains the controller of patient data. Settlements between the parties are decided by the contract, which is why the scope of the vendor’s liability should be described in it explicitly.

Do contracts signed before the KSC amendment have to be amended?

The Act does not order contracts to be amended, but it does require a secure supply chain. If the contract with a critical supplier does not regulate incident notification, remote access or data export, an annex is the simplest way to close the gap. For entities that met the criteria on 3 April 2026, the deadline for implementing the obligations is 3 April 2027.

Should a clinic outside the KSC Act also set requirements for its software vendor?

Yes, because the duties under the GDPR, the Patient Rights Act and the medical records regulation do not depend on the size of the provider. The processing agreement, authorisations for the people maintaining the system, updates and the ability to export data concern every entity that keeps medical records.

How we can help

At Remote Admin we review the contracts and access of medical software vendors as part of the NIS2 / KSC audit, prepare questionnaires and clause templates, and as a vCISO run ongoing supervision: the supplier register, annual reviews and test notifications. We also test medical systems before acceptance and after major changes, which gives a vendor a report to show before a hospital asks for one. Pricing is by custom quote. Write to us through the contact form and tell us how many hospital environments your team connects to remotely or, if you are a provider, how many companies have remote access to your systems.